Portable Folding Steam Sauna Tent with Remote Control CSA-316

Portable Folding Steam Sauna Tent with Remote Control CSA-316 product view
CSauna product reference image for RFQ review.
CSA-316 / Outdoor sauna

Specifications and options for CSA-316

Use CSA-316 as the visual reference, then confirm capacity, size, heater voltage, wood finish, glass direction, MOQ, packing, and document needs before quotation.

Model / SKU CSA-316
Product type Outdoor sauna
MOQ Confirmed by order quantity, selected configuration, and destination before quotation
Quotation basis Selected configuration, heater route, destination, packing, and project requirements confirmed before quotation
Reference CSauna factory catalog record
Confirmation items Dimensions, packing, material details, and order drawings are confirmed before production.
Heater Steam heater route; voltage and power confirmed by room volume

Buyer spec snapshotCSA-316 quote checks
Regional voltageElectrical configuration is confirmed with the selected heater and destination market; the approved drawing records the applicable voltage, phase, plug, and control route.
Heater powerHeater capacity is confirmed from room volume, insulation, heater route, and destination electrical standard.
MOQ / sampleSample, mixed-container, and repeat-order scope is quoted after the model, destination, and packing requirements are reviewed.
Wood / glue / coatingWood species and finish to confirm; sauna adhesive and oil, stain, carbonized, or black finish samples confirmed before production
Packing / CBMCarton or crate, CBM, labels, manuals, spare parts, and loading photos confirmed before shipment
Market documentsApplicable component certificates, labels, manuals, and inspection records are reviewed by project and destination.

Use CSA-316 as the visual model reference. Final size, bench layout, heater, glass, voltage, packing, and document route are locked after the approved drawing.

Known vs. confirm before production

Recorded for review Model title, model code, MOQ reference, price band, product type, and image set.
Confirm with buyer Final dimensions, material grade, heater option, glass/door direction, packing size, loading plan, labels, accessories, and destination requirements.
Approval step CSauna confirms the final drawing, quotation, packing details, and order record before production starts.

RFQ checklist for this model

  • Target quantity and whether this is sample, distributor, or project order.
  • Preferred size, wood/finish, heater type, voltage, and control option.
  • Destination port or delivery country for freight and compliance review.
  • Packaging, logo/private label, spare parts, and document requirements.
  • Any site drawing, showroom reference, or installation constraint.

Send us this model code

CSA-316 | bennett@csauna.com | WhatsApp / Phone: +86 180 7047 6405

Email CSauna

Production confirmation

What CSauna checks before CSA-316 is quoted

CSA-316 should make remote control visible as an order-file item, not just a marketing phrase.

The buyer should approve remote type, button language, timer range, generator pairing, spare remote naming, and manual photos.

Folding fabric, frame pole count, zipper direction, hose entry, folded size, and carry bag should be reviewed together.

Generator inclusion, wattage, water capacity, plug type, and voltage label should be stated before price comparison.

Factory QC should show remote operation, generator test if included, hose route, tent assembly, folded pack, labels, and carton marks.

If the remote is changed, carton data, manual screenshots, warning card, and service replacement names should change too.

For retail buyers, CSauna should prepare remote battery note, label language, carton artwork, barcode space, and warranty card.

Portable steam use needs safety notes for water filling, steam outlet, drying, electrical placement, cooling, and storage.

The page should make CSA-316 a remote-control steam kit rather than another repeated tent page.

Repeat orders should lock remote type, generator scope, voltage label, plug type, folded size, and carton marks.

Final buyer confirmation

Final approval should include remote type, generator scope, wattage, voltage label, plug type, and carton marks.

Packing evidence should show remote, generator, hose, tent, frame, carry bag, manual, and connectors.

If remote batteries are buyer-supplied, the manual and packing list should say so.

Service files should name remote, controller, generator, hose, zipper, frame poles, and connector references.

Safety notes should cover remote use, water filling, steam outlet, drying, electrical placement, and storage.

Order-file completion

CSA-316 approval notes before quotation

  • CSA-316 needs the remote-control scope written clearly, including remote type, button language, timer range, generator pairing, battery note, and spare remote name.
  • The buyer file should separate folding tent, frame poles, steam hose, generator option, remote, seat or mat, carry bag, labels, and connector pack.
  • Electrical approval should record generator wattage, water capacity, plug type, voltage market, warning language, and whether the remote is packed with batteries.
  • QC evidence should show remote operation, generator test if included, hose route, tent assembly, folded pack, label close-up, manual, and carton marks.
  • Retail orders should confirm package weight, barcode space, carton artwork, warning card, replacement hose, remote service note, and drying instructions.

Power and voltage

CSA-316 remote-control steam-generator planning

Heater powerPortable steam generator rather than a stone heater. A single-user folding tent is normally reviewed around 0.8-1.5 kW generator input; the supplied nameplate controls final wattage, water capacity, timer, and steam-output rating.
Regional voltage routeNorth America: normally 120 V. Europe and Southeast Asia: normally 220-240 V. Confirm 50/60 Hz, grounded outlet, destination plug, circuit capacity, and GFCI or RCD protection.
Approval handoffThe approved buyer file must identify generator wattage, voltage, plug, water tank, hose, timer, remote functions, fabric temperature limit, warning labels, and exact generator certification evidence.


Request quote for CSA-316