Portable Far Infrared Steam Sauna Room CSA-544

Portable Far Infrared Steam Sauna Room CSA-544 product view
CSauna product reference image for RFQ review.
CSA-544 / Infrared sauna

CSA-544 quote scope: Portable Far Infrared Steam Sauna Room

Use CSA-544 as the model reference for portable far infrared steam sauna room. Confirm final size, capacity, heater voltage and power, wood or finish, glass and door direction, MOQ, packing, certificates, and destination before quotation.

Model / SKU CSA-544
Product type Infrared sauna
MOQ 1 set
Reference price $39-49 / set
Reference CSauna factory catalog record
Confirmation items Dimensions, packing, material details, and order drawings are confirmed before production.
Heater Far infrared system; voltage and controller confirmed by market

Buyer spec snapshotCSA-544 quote checks
Regional voltageUS/Canada, EU/UK, Southeast Asia, Oceania, and 380-415V three-phase routes reviewed by market
Heater powerInfrared wattage and controller matched to cabin layout
MOQ / sampleSample, mixed-container, and repeat-order scope reviewed before quote
Wood / glue / coatingWood species and finish to confirm; sauna adhesive and oil, stain, carbonized, or black finish samples confirmed before production
Packing / CBMCarton or crate, CBM, labels, manuals, spare parts, and loading photos confirmed before shipment
Market documentsCE, ETL, SAA, label, manual, and inspection file route reviewed by project and destination

Use CSA-544 as the visual model reference. Final size, bench layout, heater, glass, voltage, packing, and document route are locked after the approved drawing.

Send us this model code

CSA-544 | bennett@csauna.com | WhatsApp / Phone: +86 180 7047 6405

Email CSauna

Buyer and factory scope

CSA-544 details to confirm before quote

CSA-544 is reviewed as a portable far infrared steam sauna room, so the buyer file should preserve the real model difference instead of using a broad sauna-room template. Best-fit buyer: buyers comparing portable sauna solutions where infrared and steam claims must be separated carefully. Material route: portable shell or frame route with heat-safe surfaces, fold or move method, electrical safety, and packing protection. Heat and electrical route: infrared and steam route with panel wattage, steamer power, controller, water responsibility, ventilation, and voltage noted separately.

Quote checks

  • For Europe and many Southeast Asia orders, the electrical note should distinguish 220-240 V from 380-415 V and name the installer responsibility.
  • For North America, the buyer file should clarify 240 V planning, English label language, and certification discussion before production release.
  • A first sample can start from 1 set for material, heat-system, glass, and packing approval; repeat MOQ should wait until the fixed configuration is approved.
  • Mixed-container planning should separate shell size, heat system, glass crate, accessory cartons, manuals, labels, spare parts, and loading sequence.
  • CSA-544 should clarify whether infrared, steam, or both are included because portable buyers often compare very different systems.

Factory handoff

  • The buyer should confirm foldable, movable, or compact fixed-room expectation before the structure is quoted.
  • Steam components should be kept away from infrared wiring unless the design file shows a safe separation.
  • Factory photos should show frame or shell, infrared panels, steamer pack, controller, ventilation, cable exit, and packed accessory bags.
  • If the product is shipped as a portable unit, carton strength and replacement electrical parts become more important than a normal cabin crate.
  • The quote should separate portable shell, infrared panels, steam kit, controller, wiring, manuals, labels, packing, and spare parts.
  • Certification discussion should follow the final electrical configuration, not the generic portable sauna category.
  • CSA-544 should not be described as a wooden outdoor cabin unless the buyer changes the structural route.
  • CSA-544 should show final size, capacity, bench direction, door swing, glass or window position, ventilation, and heat-system clearance before production release.
  • CSauna should keep CSA-544 structure, material, heat route, documents, accessories, packing, and loading terms on one handoff record.


Design department notes

CSA-544 notes for buyer review

For CSA-544, portable, infrared, and steam claims must be separated so the buyer knows exactly which system is included.

The buyer should confirm whether the structure is foldable, movable, or simply compact before carton and accessory planning starts.

Steam components should not share a vague electrical line with infrared panels because water and wiring responsibilities differ.

Factory photos should show the portable shell or frame, infrared panels, steamer pack, controller, cable exit, ventilation, and packed bags.

Certification discussion should follow the final electrical configuration instead of the broad portable sauna category.

CSA-544 should not be described as an outdoor wood cabin unless the buyer changes the structure and material route.


CSA-544 final buyer-file notes

  • CSA-544 should include a final system-definition note stating whether the portable unit is infrared only, steam only, or a combined configuration.
  • The buyer file should identify carton handling expectations because portable sauna packages are more likely to move through small warehouses.
  • If both steam and infrared are included, water-side parts and electrical parts should be packed and labeled separately.
  • The final manual should not describe outdoor cabin installation if the delivered product is a portable indoor unit.

Power and voltage

CSA-544 portable infrared and steam system definition

Heater powerThe buyer file must define infrared only, steam only, or a deliberately combined configuration. A portable infrared route is normally reviewed around 0.8-1.8 kW panel input; a portable steam route around 0.8-1.5 kW generator input. Combined supply must list both loads separately.
Regional voltage routeNorth America: normally 120 V or 240 V according to the selected system and combined load. Europe and Southeast Asia: normally 220-240 V. Confirm 50/60 Hz, plug or hardwire route, separate water-side protection, circuit capacity, controller inputs, and GFCI or RCD requirements.
Approval handoffThe approved buyer file must list included heat route, infrared panel wattages, steam-generator wattage where supplied, total simultaneous load, controller, plug, hose and cable separation, ventilation, warning labels, packing list, and exact certification evidence.