Custom Size Outdoor Low-EMF Infrared Sauna Cabin for Hotels CSA-374

Custom Size Outdoor Low EMF Infrared Sauna Cabin for Hotel Projects CSA-374 product view
CSauna product reference image for RFQ review.
CSA-374 / Infrared sauna

Model details to confirm

Use CSA-374 as the visual reference, then confirm capacity, size, heater voltage, wood finish, glass direction, MOQ, packing, and document needs before quotation.

Model / SKU CSA-374
Product type Infrared sauna
Use setting Outdoor
Heater Far infrared system; voltage and controller confirmed by market
MOQ 1 set
Reference price $2,150-2,350 / set
Reference CSauna factory catalog record
Confirmation items Dimensions, packing, material details, and order drawings are confirmed before production.

Buyer spec snapshotCSA-374 quote checks
Regional voltageUS/Canada, EU/UK, Southeast Asia, Oceania, and 380-415V three-phase routes reviewed by market
Heater powerInfrared wattage and controller matched to cabin layout
MOQ / sampleSample, mixed-container, and repeat-order scope reviewed before quote
Wood / glue / coatingWood species and finish to confirm; sauna adhesive and oil, stain, carbonized, or black finish samples confirmed before production
Packing / CBMCarton or crate, CBM, labels, manuals, spare parts, and loading photos confirmed before shipment
Market documentsCE, ETL, SAA, label, manual, and inspection file route reviewed by project and destination

Use CSA-374 as the visual model reference. Final size, bench layout, heater, glass, voltage, packing, and document route are locked after the approved drawing.

Known vs. confirm before production

Recorded for review Model title, model code, MOQ reference, price band, product type, and image set.
Confirm with buyer Final dimensions, material grade, heater option, glass/door direction, packing size, loading plan, labels, accessories, and destination requirements.
Approval step CSauna confirms the final drawing, quotation, packing details, and order record before production starts.

RFQ checklist for this model

  • Target quantity and whether this is sample, distributor, or project order.
  • Preferred size, wood/finish, heater type, voltage, and control option.
  • Destination port or delivery country for freight and compliance review.
  • Packaging, logo/private label, spare parts, and document requirements.
  • Any site drawing, showroom reference, or installation constraint.

Send us this model code

CSA-374 | bennett@csauna.com | WhatsApp / Phone: +86 180 7047 6405

Email CSauna

Product specification notes

CSA-374 custom size outdoor low-EMF infrared sauna buyer file

Model role Custom infrared outdoor cabin for hotel projects and wellness programs that need size flexibility, emitter planning, and low-EMF evidence control.
Material check Confirm custom exterior size, interior wood, exterior finish, roof route, glass scope, bench boards, emitter wall positions, door hardware, and base detail.
Power / heat route Record infrared emitter type, panel count, wattage, controller, sensor, cable path, 110-120 V or 220-240 V market, hardwire route, and low-EMF proof requirement.
MOQ / order route One sample set can be used for review when voltage, finish, label, and packing are fixed. Distributor or project orders should confirm repeated SKU files before bulk pricing.
Packing scope Separate custom panels, emitters, controller, sensor, cable set, roof pack, glass crate, bench boards, hardware, labels, manual, and crate marks.
Certificate file Keep emitter labels, controller label, voltage label, wiring photos, low-EMF evidence if requested, QC power test, packing photos, and warning label language.
RFQ direction Ask for custom size, hotel site, voltage market, emitter count, low-EMF document need, roof finish, glass direction, MOQ, crate limit, labels, and manual language.

Production confirmation

What CSauna checks before CSA-374 is quoted

CSA-374 should be treated as a custom infrared project, not a standard outdoor heater-stone sauna.

Custom size affects emitter count, cable route, bench layout, roof parts, and crate dimensions.

Low-EMF language should be supported by the actual emitter and wiring package selected.

Hotels may need clearer manual language, staff maintenance notes, and spare emitter lists.

The buyer should approve custom drawings before any label or carton file is printed.

CSauna should photograph emitter labels, controller display, cable path, glass protection, and custom panel marks.

The quote should separate custom shell, infrared system, controller, glass, roof, labels, packing, and documents.

This page should help project buyers understand which technical details shape the quote.

Final buyer confirmation

Final approval should include custom size, emitter map, wattage, voltage, low-EMF evidence need, roof route, glass scope, and crate size.

MOQ can be one hotel sample room, with batch supply only after drawing, label, and manual files are locked.

After-sales records should name emitters, controller, sensor, cable set, glass hardware, custom panels, roof trim, bench boards, and labels.

Final order file

CSA-374 buyer approval details

  • Before CSA-374 moves forward, the custom size drawing should show emitter map, cable route, roof finish, glass direction, low-EMF evidence need, and crate size.
  • Hotel buyers should approve label language, controller language, maintenance notes, spare emitter names, and manual files before production.
  • After-sales records should name emitters, controller, sensor, cable set, custom panels, glass hardware, roof trim, bench boards, and warning labels.

Project handoff note

For hotel projects, the final infrared drawing should show each emitter position against the custom wall size, the cable route to the controller, the service side for replacement parts, and the carton group used for the custom panels. This keeps the low-EMF request, electrical label, and project drawing aligned before production.

Power and voltage

CSA-374 custom-size low-EMF infrared planning

Heater powerFar-infrared panel system. Because this is a custom-size hotel cabin, heater power is calculated from the approved panel map rather than assigned from the exterior image; a typical project review may fall around 2.0-6.0 kW total installed panel power.
Regional voltage routeNorth America: normally configure 240 V for larger custom loads, with 120 V considered only when the approved load permits it. Europe and Southeast Asia: normally 220-240 V. Confirm 50/60 Hz, phase, circuit capacity, controller, cable entry, and project-electrician scope.
Approval handoffThe approved drawing must show cabin size, every panel position and wattage, total heater power, controller, sensor, wiring harness, service access, and the measurement method supporting any low-EMF claim.