Two Person Outdoor Far Infrared Sauna with Timer Control CSA-393

2 Person Outdoor Far Infrared Sauna with Timer Control CSA-393 product image
CSauna product reference image for RFQ review.
CSA-393 / Infrared sauna

CSA-393 quote scope: 2 Person Outdoor Far Infrared Sauna with Timer Control

Use CSA-393 as the model reference for 2 person outdoor far infrared sauna with timer control. Confirm final size, capacity, heater voltage and power, wood or finish, glass and door direction, MOQ, packing, certificates, and destination before quotation.

Model / SKU CSA-393
Product type Infrared sauna
Use setting Outdoor
Capacity 2 person
Heater Far infrared system; voltage and controller confirmed by market
MOQ 1 set
Reference price $1,400-1,600 / set
Reference CSauna factory catalog record
Confirmation items Dimensions, packing, material details, and order drawings are confirmed before production.

Buyer spec snapshotCSA-393 quote checks
Regional voltageUS/Canada, EU/UK, Southeast Asia, Oceania, and 380-415V three-phase routes reviewed by market
Heater powerInfrared wattage and controller matched to cabin layout
MOQ / sampleSample, mixed-container, and repeat-order scope reviewed before quote
Wood / glue / coatingWood species and finish to confirm; sauna adhesive and oil, stain, carbonized, or black finish samples confirmed before production
Packing / CBMCarton or crate, CBM, labels, manuals, spare parts, and loading photos confirmed before shipment
Market documentsCE, ETL, SAA, label, manual, and inspection file route reviewed by project and destination

Use CSA-393 as the visual model reference. Final size, bench layout, heater, glass, voltage, packing, and document route are locked after the approved drawing.

Known vs. confirm before production

Recorded for review Model title, model code, MOQ reference, price band, product type, and image set.
Confirm with buyer Final dimensions, material grade, heater option, glass/door direction, packing size, loading plan, labels, accessories, and destination requirements.
Approval step CSauna confirms the final drawing, quotation, packing details, and order record before production starts.

RFQ checklist for this model

  • Target quantity and whether this is sample, distributor, or project order.
  • Preferred size, wood/finish, heater type, voltage, and control option.
  • Destination port or delivery country for freight and compliance review.
  • Packaging, logo/private label, spare parts, and document requirements.
  • Any site drawing, showroom reference, or installation constraint.

Send us this model code

CSA-393 | bennett@csauna.com | WhatsApp / Phone: +86 180 7047 6405

Email CSauna

Product specification notes

CSA-393 two person outdoor far infrared sauna with timer control buyer file

Model role Outdoor infrared sauna for homes, villas, and small resorts that need emitter placement, timer control, and weatherproof shell details.
Material check Confirm exterior cladding, interior wood, roof finish, emitter wall positions, bench boards, glass direction, door hardware, base detail, and service trim.
Power / heat route Record far infrared panel count, wattage, timer controller, sensor, cable path, 110-120 V or 220-240 V route, plug or hardwire plan, and label language.
MOQ / order route One sample set can be used for review when voltage, finish, label, and packing are fixed. Distributor or project orders should confirm repeated SKU files before bulk pricing.
Packing scope Separate outdoor panels, infrared emitters, timer controller, sensor, cable set, roof parts, bench boards, glass crate, hardware bags, labels, manuals, and crate marks.
Certificate file Keep emitter labels, controller label, voltage label, wiring route, power-on test, roof photos, glass protection, warning labels, and manual language.
RFQ direction Ask for voltage market, emitter count, timer function, outdoor finish, roof route, glass direction, MOQ, carton limit, label language, and spare emitter plan.

Production confirmation

What CSauna checks before CSA-393 is quoted

CSA-393 should be clearly infrared, not a heater-stone or steam model.

Timer control should be tied to the supplied controller and not written as a generic smart feature.

Outdoor infrared rooms need both electrical evidence and weatherproof shell notes.

The buyer should approve emitter positions before interior panels are finalized.

Voltage and plug route should be fixed before labels and manuals are printed.

CSauna should photograph emitter labels, timer controller, cable route, roof parts, glass protection, and carton marks.

The quote should separate wood shell, infrared system, timer control, roof, glass, packing, labels, and spare parts.

This page should make the timer-controlled infrared route easy to understand.

Final buyer confirmation

Final approval should include emitter map, panel wattage, timer controller, voltage, roof route, glass direction, bench layout, and carton size.

MOQ can be one sample room, with distributor batches after controller, label, manual, and spare emitter files are fixed.

After-sales records should name emitters, timer controller, sensor, cable set, roof trim, glass hardware, bench boards, and labels.

Final order file

CSA-393 buyer approval details

  • Before CSA-393 is released, emitter map, timer-control function, controller language, voltage route, roof finish, and glass direction should be checked together.
  • The QC file should show emitter labels, timer controller, cable route, sensor position, roof parts, glass protection, warning labels, and carton marks.
  • After-sales records should name emitters, timer controller, sensor, cable set, roof trim, glass hardware, bench boards, labels, and manuals.

Project handoff note

For timer-control infrared orders, CSauna confirms whether the buyer needs a simple countdown timer, a temperature-and-time controller, or a market-specific labeled control panel. The final file should connect timer function, emitter map, sensor route, voltage, glass direction, and spare controller naming before shipment.

Power and voltage

CSA-393 outdoor two-person infrared planning

Heater powerFar-infrared panel system. A two-person outdoor cabin is normally reviewed around 1.8-3.5 kW total installed panel power, calculated from approved panel count, timer-control set, glass, insulation, and outdoor conditions.
Regional voltage routeNorth America: configure 120 V or 240 V according to total load. Europe and Southeast Asia: normally 220-240 V. Confirm 50/60 Hz, weather-protected supply, circuit capacity, timer-controller input, cable entry, and local connection route.
Approval handoffThe approved drawing must show panel map, individual wattages, total heater power, timer controller, sensor, weather-protected cable entry, service access, and exact electrical labels.